Online Training. Personal Development. Work at ComAp. ComAp Worldwide. ComAp for Media. ComAp Club Search. Manuals Software Show all related files. Order and more information for your region. Compact controller for single operating gen-set Manual and remote start applications Manual control of GCB from the front panel Full gen-set monitoring and protection 3 phase power and produced energy measurement 3 analogue inputs Remote modem control Replaced with new design; we recommend using InteliLite NT MRS 16 instead.
LiteEdit 6. Discover features. Recommended by our customers ACF Standby Systems supplies reliable standby and trailer mounted generator systems to maximize customer's uptime and profitability through a total solutions approach and solid customer relationships. InteliMonitor 4. ECU List 7. Accesories Show all. Cloud Based System for remote monitoring and management of ComAp and 3rd party devices.
Show all. Applications Show all. Prime Power System. Related products Show all. Find your local contact All distributors. Solutions Industries Solutions Applications Case studies. Products Catalogue. Training Online training Hands-on Training. Submit Ticket. Find a local support specialist. Helpdesk Local department contacts Ticket form.
Services Abbreviations InteliBot. Knowledge Base Download the latest documents and manuals. About Us. Hands-on Training. Online Training. Personal Development. Work at ComAp. ComAp Worldwide. ComAp for Media. ComAp Club Search. Page Stabilization 5. There are two timers setpoints in this phase: Minimal Stabilization Time page starts to count down just after the idle period has finished. Generator voltage and frequency are not checked respective protections are not evaluated and the GCB cannot be closed even if the generator voltage and frequency are within limits.
Page Alarm Management Duration of the cool down phase is determined by the setpoint Cooling Time page Cooling is performed either at nominal speed generator voltage and frequency protections are evaluated or at idle speed generator voltage and frequency protections are not evaluated. Selection of the speed is done by the setpoint Cooling Speed page Page 83 Image 5. The categories are the following: The alarm is evaluated all the time when the controller is switched on. Page 84 Active alarm: the alarm condition persists, alarm delay has elapsed.
Inactive alarm: the alarm condition has disappeared, but the alarm has not been confirmed. Confirmed alarm: the alarm condition persists, but the alarm has already been confirmed. Image 5. Page 85 Breaker open and cool down BOC The event appears in the alarmlist and is recorded into the history log. It causes immediate opening of the GCB and then the standard stop sequence with cooling follows.
The gen-set cannot be started again while there is a BOC alarm in the alarmlist. Alarmlist Alarmlist is a container of active and inactive alarms. It will appear automatically on the controller display, if a new alarm occurs, or can be displayed manually from the display menu.
Page Breaker Control Record structure Name Abbreviation Description Row number 0 corresponds to the last record, -1 to the previous Number one, etc. Page 90 The control outputs must be configured and wiring of the power switches must be provided in such a way, that the controller has full control over the breakers — i.
In this case there is check of breaker real state. There are three different time delays for breaker fail detection — see following diagrams. Page Exercise Timers Image 5. The timers are intended for scheduling of any operations such as e.
In timer settings adjust date and time of occurrence of timer. Also adjust the duration of timer. Set-up via controller interface In controller go to the Scheduler setpoint group. Select the function of timer via Timer 1 Function page setpoint. Page 95 Image 5. In repetition type select Daily. In timer settings adjust date and time of first occurrence of timer. Also adjust the duration of each occurrence of timer. Than select the x-th day of repetition Timer 1 Refresh Period page and behavior of timer on weekends Timer 1 Weekends page Page 96 Image 5.
In repetition type select Weekly. Than select the x-th week of repetition Timer 1 Refresh Period page and days when timer should be active Timer 1 Day page Page 97 There are two types of monthly repetition. First of them is based on repeating one day in month. In repetition type select Monthly.
Page 98 Second type of monthly repetition is based on repeating days in week in month. Than select the type of monthly repetition, the x-th week of repetition and days in week. Note: First of all function of timer has to be adjusted via setpoint Timer 1 Function page Page Service Timers How to set-up rental timer This is a short guide for settings of rental timers.
Please see following few steps how to set up rental timers: Choose the type of rental timer Rental Timer 1 page based on engine running hours Rental Timer 2 page based on date Adjust the length of chosen timer Page Flowchart 5. Page Additional Running Engine Indications 5. Page Ready Gen-set is ready to run. Cooling Gen-set is cooling before stop. MAN gen-set operation. Page Sensor Curves Image 5. The controller will continuously try to stop the engine.
Page 2 Calibration page , or Analog Input 3 Calibration page , or Analog Input 4 Calibration page directly to the calculated value at analog input. Note: The calibration must be done at the operational point of the analog input e.
Default sensor curves There are 16 default resistive curves available. Page Plc 5. It has graphical interface to have user interface easy to use. Page following essential steps: Adjust the sheet to your needs.
See Working with sheets page for more information. Add PLC blocks into the sheets. See Adding PLC blocks page for more information. Define inputs and outputs of the PLC program. See Define inputs and outputs page for more information. Page Image 5. Also delete selection function can by used. Define inputs and outputs Image 5. Page Double-click on a free input position or existing input to add new input or edit the existing one.
Select the source for the input. If you create a binary input, you can select a source from following categories: Bin. Values - this category contains all binary values available in the controller as binary inputs, logical binary outputs etc. Page Outputs Sheet outputs are located at the right side of a sheet.
Follow the procedure below to add or edit an input. Doubleclick on a free output position to add new sheet output Doubleclick on an already created output to configure the output onto a controller output terminal or a logical binary input first of all some PLC block output has to be connected to this output to enable configuration of output Image 5.
Page Locate the mouse pointer over the starting point of the wire. If the area under the mouse pointer is a connection point, the pointer will change the color fill of pointer will be white. Press and hold the left mouse button and drag the wire to the destination of required connection point.
If you point over a valid connection point, the connection point will be marked with a red circle. Delete whole content of sheet Use this function to delete the whole content of sheet including blocks, wires, inputs, outputs, etc Hints Use this function to enable or disable quick hints for blocks controller help is not affected by this function.
After-Treatment screen is automatically shown, once any of selected lamps gets active or change status. Page Universal lamps icons Universal lamp icons are shown on the After-Treatment screen. Based on specific value read in specific frame with specific SPN is every lamp icon either: shown hidden blinking slow 1Hz blinking fast 2Hz Note: Lamp icon blinking is defined as displaying active lamp icon and inverse colored active lamp icon in required frequency.
This lamp also activates alarm After- Treatment page Note: This lamp also Fluid tank low level indicator activates alarm After- Treatment page Page Remote Communication 6. It is highly recommended to change these parameters. Different port numbers can be used to create multiple port forwarding rules in the same local network. Page start Start the engine in MAN mode. Switching to OFF mode. It is not recommended to expose the web interface to the public Internet. The Web Server is designed for basic monitoring and adjustment of the controller using a web browser.
The scada page is also the main page which is displayed by default if you just put the CM-Ethernet address into the browser after entering the right access code. Then click to the required group name in the left box to display values of the group in the right box.
Note: The measurement page is automatically refreshed every 60 seconds this time cannot be changed. Image 6.
0コメント